specbos 1211(UV+VIS+IR)
specbos 1211 is a miniaturized and fast broadband spectroradiometer covering the wavelength range from VIS(UV) to NIR. It can be used for various applications both in lab as well as in production. The instrument is available in a standard version for the wavelength range of 350 ... 1000 nm and in an extended UV version (specbos 1211UV) with 230 ... 1000 nm.
Optical Parameters | |
Spectral range | specbos 1211 : 350 nm - 1000 nm specbos 1211UV : 230 nm - 1000 nm |
Optical resolution (FWHM) | 4.5 nm |
Calculated wavelength step | 1 nm |
Digital electronic resolution | 16 Bit ADC (15 Bit used) |
Viewing angle | 1.8° (Luminance mode) |
Measuring distance / diameter | 20 cm - Ø 6 mm; 100 cm - Ø 31 mm (luminance mode) |
Measuring values | Spectral radiance Total luminance/ total radiance Total illuminance/ total irradiance Chromaticity coordinates x , y ; u', v' Correlated Color Temperature, color purity Color Rendering Index, RGB Circadian metrics, Photosynthetically Active Radiation |
Measuring ranges and accuracies | |
Measuring range luminance | 0.1 - 7 500 cd/m² (higher values with optional filter) @ illuminant A |
Measuring range illuminance | 2 - 60 000 lx @ illuminant A |
Luminance accuracy | ± 2 % @ 100 cd/m² and illuminant A |
Luminance reproducibility | ± 1 %@ 100 cd/m² and illuminant A |
Chromaticity accuracy | ± 0.002 x , y @ illuminant A |
Color reproducibility | ± 0.0005 x , y @ illuminant A |
CCT reproducibility | ± 20 K @ illuminant A |
Wavelength accuracy | ± 0.5 nm |
Other technical data | |
Dispersive element | Imaging grating (flat field) |
Light receiving element | CCD array 2048 pixel |
Power supply | USB powered (no voltage < 4.8V) |
PC interface | USB 2.0 fullspeed |
Dimensions (drawing) | 180 mm * 82 mm * 53 mm |
Weight | 450 g |
Operating conditions | Temperature 10 - 40 °C Humidity < 85 % relative humidity at 35 °C |
Miscellaneous | |
All inclusive accessories packet |
Cosine corrector head-piece (for irradiance measurement) Tripod Transport box PC software JETI LiVal JETI SDK Operating instructions and firmware commands (digital) USB cable Trigger connector |
Calibration | NIST traceable |
Recommended recalibration interval | 1 year |
Each front end accessory changes the sensitivity of the instrument, therefore an individual calibration file is necessary for each accessory. Both specbos 1201 and 1211 can store up to 8 calibration sets. The front ends can be coded that up to three calibration files will be selected automatically if the related accessory is attached (the fourth is the calibration of the instrument without accessory).
Related products
More
More
More
More
More
More
More
More
More
More