specbos 1211(UV+VIS+IR)

specbos 1211 is a miniaturized and fast broadband spectroradiometer covering the wavelength range from VIS(UV) to NIR. It can be used for various applications both in lab as well as in production. The instrument is available in a standard version for the wavelength range of 350 ... 1000 nm and in an extended UV version (specbos 1211UV) with 230 ... 1000 nm.

  • Printer
Optical Parameters
   Spectral range    specbos 1211 :         350 nm - 1000 nm    
   specbos 1211UV :     230 nm - 1000 nm
   Optical resolution (FWHM)    4.5 nm
   Calculated wavelength step    1 nm
   Digital electronic resolution    16 Bit ADC (15 Bit used)
   Viewing angle    1.8° (Luminance mode)
   Measuring distance / diameter    20 cm - Ø 6 mm; 100 cm - Ø 31 mm (luminance mode)
   Measuring values    Spectral radiance    
   Total luminance/ total radiance 
   Total illuminance/ total irradiance 
   Chromaticity coordinates x , y ; u', v'
   Correlated Color Temperature, color purity
   Color Rendering Index, RGB
   Circadian metrics, Photosynthetically Active Radiation
Measuring ranges and accuracies
   Measuring range luminance    0.1 - 7 500 cd/m² (higher values with optional filter) @ illuminant A
   Measuring range illuminance    2 - 60 000 lx @ illuminant A
   Luminance accuracy    ± 2 % @ 100 cd/m² and illuminant A
   Luminance reproducibility    ± 1 %@ 100 cd/m² and illuminant A
   Chromaticity accuracy    ± 0.002 x , y @ illuminant A
   Color reproducibility    ± 0.0005 x , y @ illuminant A
   CCT reproducibility    ± 20 K @ illuminant A
   Wavelength accuracy    ± 0.5 nm
Other technical data
   Dispersive element    Imaging grating (flat field)
   Light receiving element    CCD array 2048 pixel
   Power supply    USB powered (no voltage < 4.8V)
   PC interface    USB 2.0 fullspeed
   Dimensions (drawing)    180 mm * 82 mm * 53 mm
   Weight    450 g
   Operating conditions    Temperature 10 - 40 °C
   Humidity < 85 % relative humidity at 35 °C
Miscellaneous




   All inclusive accessories packet
   Cosine corrector head-piece  (for irradiance measurement) 
   Tripod
   Transport box
   PC software JETI LiVal 
   JETI SDK 
   Operating instructions and firmware commands (digital)
   USB cable
   Trigger connector
   Calibration    NIST traceable
   Recommended recalibration interval    1 year
Each front end accessory changes the sensitivity of the instrument, therefore an individual calibration file is necessary for each accessory. Both specbos 1201 and 1211 can store up to 8 calibration sets. The front ends can be coded that up to three calibration files will be selected automatically if the related accessory is attached (the fourth is the calibration of the instrument without accessory).